首页
登录
职称英语
The use of heat pumps has been held back largely by skepticism about adverti
The use of heat pumps has been held back largely by skepticism about adverti
游客
2025-04-26
4
管理
问题
The use of heat pumps has been held back largely by skepticism about advertisers’ claims that heat pumps can provide as many as two units of thermal energy for each unit of electrical energy used, thus apparently contradicting the principle of energy conservation.
Heat pumps circulate a fluid refrigerant that cycles alternatively from its liquid phase to its vapour phase in a closed loop. The refrigerant, starting as a low-temperature, low-pressure vapor, enters a compressor driven by an electric motor. The refrigerant leaves the compressor as a hot, dense vapour and flows through a heat exchanger called the condenser, which transfers heat from the refrigerant to a body of air. Now the refrigerant,as a high-pressure, cooled liquid, confronts a
flow restriction
which causes the pressure to drop. As the pressure falls, the refrigerant expands and partially vaporizes, becoming chilled. It then passes through a second heat exchanger, the evaporator, which transfers heat from the air to the refrigerant, reducing the temperature of this second body of air. Of the two heat exchangers, one is located inside, and the other one outside the house, so each is in contact with a different body air: room air and outside air, respectively.
The flow direction of refrigerant through a heat pump is controlled by valves. When the refrigerant flow is reversed, the heat exchangers switch function. This flow-reversal capability allows heat pumps either to heat or cool room air.
Now, if under certain conditions a heat pump puts out more thermal energy than it consumes in electrical energy, has the law of energy conservation been challenged? No, not even remotely: the additional input of thermal energy into the circulating refrigerant via the evaporator accounts for the difference in the energy equation.
Unfortunately, there is one real problem. The heating capacity of a heat pump decreases as the outdoor temperature falls. The drop in capacity is caused by the lessening amount of refrigerant mass moved through the compressor at one time. The heating capacity is proportional to this mass flow rate: the less the mass of refrigerant being compressed, the less the thermal load it can transfer through the heat-pump cycle. The volume flow rate of refrigerant vapor through the singlespeed rotary compressor used in heat pumps is approximately constant. But cold refrigerant vapor entering a compressor is at lower pressure than warmer vapor. Therefore, the mass of cold refrigerant—and thus the thermal energy it carries is less if the refrigerant vapor were warmer before compression.
Here, then, lies a genuine drawback of heat pumps: in extremely cold climates heat is needed—heat pumps are least able to supply enough heat. (441 words) [br] The author resolves the question of whether heat pumps run counter to the principle of energy conservation by______.
选项
A、carefully clarifying the meaning of that principle
B、explaining that heat pumps can cool, as well as heat, room air
C、supplying additional relevant facts
D、denying the relevance of that principle to heat pumps
答案
A
解析
在第一段最后,作者提出热泵广告违反了能量守恒定律,然后在第二段到第四段详细叙述了热泵的工作原理,从而使大众弄清热泵与能量守恒定律之间的关系,故选A。
转载请注明原文地址:https://tihaiku.com/zcyy/4053934.html
相关试题推荐
Theuseofheatpumpshasbeenheldbacklargelybyskepticismaboutadverti
Thereisanewtypeofadvertisementbecomingincreasinglycommoninnewspap
Thereisanewtypeofadvertisementbecomingincreasinglycommoninnewspap
Thereisanewtypeofadvertisementbecomingincreasinglycommoninnewspap
Thereisanewtypeofadvertisementbecomingincreasinglycommoninnewspap
Manycountrieswillnotallowcigaretteadvertisingintheirnewspapersoro
Manycountrieswillnotallowcigaretteadvertisingintheirnewspapersoro
Manycountrieswillnotallowcigaretteadvertisingintheirnewspapersoro
Manycountrieswillnotallowcigaretteadvertisingintheirnewspapersoro
Manycountrieswillnotallowcigaretteadvertisingintheirnewspapersoro
随机试题
Einsteinworkedoutthetheoryofrelativitywithpaperandpencil,butcouldon
[originaltext]W:Hi,David.M:Hi,Laura.W:Howwasyourfinal?M:Absolutely
影响身体平衡的因素不正确的是A.支持面的大小 B.稳定极限的大小 C.神经系
A.0~20 B.20~25以下 C.20~35/25~40 D.35~5
交易撮合时的操作要点主要包括()。A.分析双方的经济实力差距 B.分析双方
共用题干 第二篇One一RoomSchoolsOne-roomsohool
颅盖线形骨折的诊断主要依据()。A.X线摄片 B.MRl检查 C.临床检查
行政复议不适用于下列哪项原则?()。A.调解 B.便民 C.准确
根据案例材料,回答题 求助者一般资料:周女士,26岁,某公司职员。 病症:最
A.空腹血糖 B.糖基化血红蛋白 C.尿糖 D.胰岛素释放试验 E.葡萄
最新回复
(
0
)